Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 83
Filter
1.
The Journal of Korean Academy of Prosthodontics ; : 497-507, 2021.
Article in English | WPRIM | ID: wpr-918860

ABSTRACT

All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient’s inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient’s requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

2.
The Journal of Korean Academy of Prosthodontics ; : 306-312, 2020.
Article in English | WPRIM | ID: wpr-837274

ABSTRACT

Purpose@#The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month postplacement. @*Materials and Methods@#A total of 12 implants were assessed in 12 patients for the sites where 0.5 - 1.5 mm labial bone was covering the implants, using CBCT. @*Results@#A statistically significant preservation of crestal bone was observed in the narrow-diameter implants. @*Conclusion@#Guided flapless implant surgery may be important in preventing bone loss around the narrow-diameter implants that are placed in narrow alveolar ridges.

3.
Journal of the Korean Society of Emergency Medicine ; : 401-419, 2020.
Article | WPRIM | ID: wpr-834895

ABSTRACT

Objective@#This study aimed to investigate the perception of emergency medical service (EMS) providers and medical directors toward the field skill proficiency of EMS providers. We further examined differences in perception according to the certification and hospital career of individuals. @*Methods@#This survey was conducted enrolling all active EMS providers in Busan, Ulsan, and Gyeongnam, as well as emergency physicians who participated in direct medical direction. Pre-developed questionnaires were sent as text messages to individual EMS providers and emergency physicians using an internet-based survey tool (Google Forms).Questionnaires were composed of 25 items in 7 categories: “airway management”, “ventilatory support”, “circulatory support”, “field assessment and management of trauma patients”, “field assessment and management of patients with chest pain”, “field assessment and management of patients with neurologic symptoms”, and “other items”. The response was based on a five-point Likert scale, where 0 score indicated no experience at all. @*Results@#The questionnaire was distributed to 1,781 EMS providers and 52 medical directors; of these, 1,314 (73.7%) EMS providers and 34 (65.3%) medical directors completed the survey. EMS providers rated themselves as above average (3 points) for most of the questions. However, the majority responded that they had no experience or low proficiency in endotracheal intubation and prehospital delivery (median 2; interquartile range [IQR], 0-3). Conversely, medical directors assessed the EMS provider’s proficiency as above average in use of I-gel, recognition of hypoglycemia, field management of trauma patients, use of oropharyngeal and nasopharyngeal airway, use of laryngeal mask airway, and optimal oxygen supply (median, 4; IQR, 3-4), but responded with low scores for most other questions. Based on the EMS provider certification, nurses scored themselves more proficient than level-1 emergency medical technicians (EMTs) for intravenous access (P<0.001), whereas level-1 EMTs recognized themselves more proficient than nurses for endotracheal intubation (P<0.001), use of Magill forceps (P=0.004), and pediatric cardiopulmonary resuscitation (P<0.001). @*Conclusion@#This study recognized the discrepancies in the perception of EMS provider’s field skill proficiency, as perceived by EMS providers and medical directors, and between level-1 EMTs and nurses. We propose that regional EMS authorities need to make persistent efforts to narrow these perception gaps through effective educational programs for EMS providers and medical directors.

4.
Journal of the Korean Society of Emergency Medicine ; : 483-503, 2020.
Article in Korean | WPRIM | ID: wpr-901174

ABSTRACT

Objective@#This study investigated the current work status of emergency medical services (EMS) personnel and the differences in perception between EMS personnel and medical directors (MD) regarding on-line medical oversight in a province. @*Methods@#A total of 1,781 EMS personnel and 51 medical directors were surveyed. The questionnaire consisted of the basic demographic data, work status, perception of on-line medical oversight, and the upcoming national pilot project of the expanding firefighter EMS personnel’s clinical scope. The survey was conducted from May 17 to 27, 2019. @*Results@#The response rates for EMS personnel and MD were 73.7% and 65.3%, respectively. Of the local EMS personnel, 86.8% were male. The average age and field career was 33.5±6.2 years and 50 months, respectively. The proportion of nurse and 1st-grade emergency medical technicians were 30.6% and 35.7%. The EMS personnel and MD answered ‘on-scene basic life support’ and ‘patient’s refusal of transport’, respectively, as the most unnecessary medical oversight. Both responded to the main problem of current medical oversight as ‘request for unnecessary medical oversight.’ EMS personnel responded that all items in the national pilot project of expanding firefighter EMS personnel’s clinical scope would be helpful, while MD reported that only ‘use of epinephrine in anaphylactic patient’ and ‘use of pre-hospital 12 lead electrocardiogram in chest pain patient’ would helpful (P<0.01). @*Conclusion@#There was a certain difference in perception of the most unnecessary medical oversight and the upcoming national pilot project of expanding the clinical scope of firefighter EMS personnel between EMS personnel and MD.

5.
Journal of the Korean Society of Emergency Medicine ; : 483-503, 2020.
Article in Korean | WPRIM | ID: wpr-893470

ABSTRACT

Objective@#This study investigated the current work status of emergency medical services (EMS) personnel and the differences in perception between EMS personnel and medical directors (MD) regarding on-line medical oversight in a province. @*Methods@#A total of 1,781 EMS personnel and 51 medical directors were surveyed. The questionnaire consisted of the basic demographic data, work status, perception of on-line medical oversight, and the upcoming national pilot project of the expanding firefighter EMS personnel’s clinical scope. The survey was conducted from May 17 to 27, 2019. @*Results@#The response rates for EMS personnel and MD were 73.7% and 65.3%, respectively. Of the local EMS personnel, 86.8% were male. The average age and field career was 33.5±6.2 years and 50 months, respectively. The proportion of nurse and 1st-grade emergency medical technicians were 30.6% and 35.7%. The EMS personnel and MD answered ‘on-scene basic life support’ and ‘patient’s refusal of transport’, respectively, as the most unnecessary medical oversight. Both responded to the main problem of current medical oversight as ‘request for unnecessary medical oversight.’ EMS personnel responded that all items in the national pilot project of expanding firefighter EMS personnel’s clinical scope would be helpful, while MD reported that only ‘use of epinephrine in anaphylactic patient’ and ‘use of pre-hospital 12 lead electrocardiogram in chest pain patient’ would helpful (P<0.01). @*Conclusion@#There was a certain difference in perception of the most unnecessary medical oversight and the upcoming national pilot project of expanding the clinical scope of firefighter EMS personnel between EMS personnel and MD.

6.
The Journal of Korean Academy of Prosthodontics ; : 88-94, 2018.
Article in Korean | WPRIM | ID: wpr-742085

ABSTRACT

Recently, digital implant systems are expanding its influence in dental area. Due to technical improvement, they jumped over their limits nowadays. We can use these newest systems to treat edentulous patient, from implant surgery to fabrication of prosthesis. In this case, The patient was a fifty years old female. She had a full edentulous ridge on mandible and wanted to reconstruct occlusion with using implants. We planned to use digital implant system with “all-on-4” concept on mandible and produced surgical guide for flapless implant surgery. After the surgery, we tried to fabricate full arch prosthesis just using a digital devices and confirmed satisfying result.


Subject(s)
Female , Humans , Mandible , Prostheses and Implants
7.
The Journal of Korean Academy of Prosthodontics ; : 330-337, 2018.
Article in Korean | WPRIM | ID: wpr-717295

ABSTRACT

In edentulous patients, implant - supported fixed prosthesis treatment has been proved to be useful, but involves complex treatment process. On the other hand, in the modern dentistry, digital technology has been developed day by day and it has expanded its range to the implant restoration of edentulous patients. In this case, a digital system was used for all stages of diagnosis, surgery, design and fabrication of provisional implants fixed prosthesis restoration in 66-year-old mandibular edentulous patients. In the preoperative diagnosis stage, a provisional restoration was designed based on the mucosal scan using the intraoral scanner and the stable occlusion of prefabricated complete denture of the patient. After flapless implant surgery using the surgical guide, the prefabricated interim restoration was connected to the implant and used as immediate provisional restoration. The final restoration was designed and fabricated by transferring the vertical dimension and the centric relation of the provisional restoration with stable occlusion using digital technology. We report a simple protocol of implant treatment in edentulous patients by using digital techniques to preserve the patient's vertical dimension and occlusion.


Subject(s)
Aged , Humans , Centric Relation , Dentistry , Denture, Complete , Diagnosis , Hand , Printing, Three-Dimensional , Prostheses and Implants , Vertical Dimension
8.
Journal of the Korean Society of Emergency Medicine ; : 475-483, 2017.
Article in Korean | WPRIM | ID: wpr-124959

ABSTRACT

PURPOSE: To define early predictors of critical cases involving patients who visited the emergency department (ED) due to gas inhalation, with the goal of identifying patients who require intensive monitoring and treatment. METHODS: The retrospective study was carried out for patients who visited the ED at Ulsan University Hospital due to gas inhalation from March 2014 to February 2016. General demographics, mechanism of accident, critical symptoms, vital signs, blood lab test results, severity, and clinical manifestation were investigated. Patients were divided into a critical group and non-critical group, and predictors of critical cases were investigated by comparing both groups. RESULTS: Of the 180 patients, 26 patients were in the critical group. In this group, more patients displayed altered mentality and cardiac arrest (both p<0.001). The critical group also showed significantly higher fractions for low-blood pressure (systolic blood pressure<90 mmHg; p<0.001), number of critical symptoms (p<0.001), transport by emergency medical services (p=0.003), and consultation involving other departments (p<0.001). Patients in the critical group showed higher Korean Triage and Acuity Scale (KTAS) level (p<0.001), lactate value (p=0.001), and carboxy-hemoglobin value (p=0.017) as well as older age (p=0.001), lower pH (p=0.001), and HCO₃⁻ value (p<0.001). Multiple regression analysis revealed that predictors of critical cases were older age and higher KTAS level (both p<0.001). CONCLUSION: Patients admitted to the ED for treatment of gas inhalation, who were older and had a higher KTAS level, require intensive monitoring and treatment.


Subject(s)
Humans , Blood Gas Analysis , Demography , Emergencies , Emergency Medical Services , Emergency Medicine , Emergency Service, Hospital , Heart Arrest , Hydrogen-Ion Concentration , Inhalation , Lactic Acid , Predictive Value of Tests , Retrospective Studies , Smoke Inhalation Injury , Triage , Vital Signs
9.
The Journal of Korean Academy of Prosthodontics ; : 61-70, 2017.
Article in Korean | WPRIM | ID: wpr-39476

ABSTRACT

In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.


Subject(s)
Humans , Dentures , Osseointegration , Prostheses and Implants
10.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 9-12, 2016.
Article in English | WPRIM | ID: wpr-202734

ABSTRACT

OBJECTIVES: In this study we evaluated heat generation during the low-speed drilling procedure without irrigation. MATERIALS AND METHODS: Ten artificial bone blocks that were similar to human D1 bone were used in this study. The baseline temperature was 37.0degrees C. We drilled into 5 artificial bone blocks 60 times at the speed of 50 rpm without irrigation. As a control group, we drilled into an additional 5 artificial bone blocks 60 times at the speed of 1,500 rpm with irrigation. The temperature changes during diameter 2 mm drilling were measured using thermocouples. RESULTS: The mean maximum temperatures during drilling were 40.9degrees C in the test group and 39.7degrees C in the control group. Even though a statistically significant difference existed between the two groups, the low-speed drilling did not produce overheating. CONCLUSION: These findings suggest that low-speed drilling without irrigation may not lead to overheating during drilling.


Subject(s)
Humans , Dental Implants , Hot Temperature
11.
The Journal of Korean Academy of Prosthodontics ; : 111-119, 2015.
Article in Korean | WPRIM | ID: wpr-87267

ABSTRACT

PURPOSE: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). MATERIALS AND METHODS: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. RESULTS: The mean deviation of the insertion point and angulation were 0.28 mm and 0.26degrees, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. CONCLUSION: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.


Subject(s)
Axis, Cervical Vertebra , Cone-Beam Computed Tomography , Mandible , Maxilla , Tooth
12.
The Journal of Korean Academy of Prosthodontics ; : 157-166, 2015.
Article in Korean | WPRIM | ID: wpr-87261

ABSTRACT

This article describes how to use CBCT and an intraoral scanner in a fully edentulous case that enables the clinician to place implants with flapless guided surgery and to engage prefabricated, customized implant abutments at the time of implant surgery, with only 1 clinical consultation before implant surgery. The patient's existing denture is used to simulate the teeth, the soft tissue and the vertical dimension of occlusion, and jaw relationship in the fully edentulous jaw. It provides clinicians with a fast workflow and improves clinical efficiency.


Subject(s)
Humans , Dentures , Jaw , Jaw, Edentulous , Tooth , Vertical Dimension
13.
Journal of The Korean Society of Clinical Toxicology ; : 33-35, 2015.
Article in Korean | WPRIM | ID: wpr-94923

ABSTRACT

A 24 year-old man attempted suicide by injection of 1 cc of thinner into his left antecubital vein; 3 hours later, he visited our emergency room because of left chest pain. We suspected a chemical pneumonitis based on the abnormal findings of his chest X-ray and computed tomography. On the 3rd day after admission, a cellulitis also occurred at the injection area. His symptoms were relieved after supportive care for 2 weeks. There is significant experience with intoxication of thinner inhalation, whereas intoxication of intravenous thinner is rare.


Subject(s)
Cellulitis , Chest Pain , Emergency Service, Hospital , Inhalation , Pneumonia , Suicide, Attempted , Thorax , Veins
14.
Annals of Pediatric Endocrinology & Metabolism ; : 111-115, 2013.
Article in English | WPRIM | ID: wpr-178358

ABSTRACT

PURPOSE: 45,XY,t(13;14)(q10;q10) karyotype can suggest infertility associated with more or less severe oligospermia in male adults. In addition, 45,XX,t(13;14)(q10;q10) karyotype carries reproductive risks such as miscarriage or infertility in female adults. However, reports on the phenotype of this karyotype in children are very rare. This study was done to observe various phenotypes of this karyotype in children. METHODS: Between January 2007 and December 2012, children diagnosed with 45,XY,t(13;14)(q10;q10) or 45,XX,t(13;14)(q10;q10) karyotype by chromosome analysis were analyzed retrospectively. RESULTS: Eight children (5 boys and 3 girls) were diagnosed with 45,XY,t(13;14)(q10;q10) or 45,XX,t(13;14)(q10;q10) karyotype. They ranged in age from 5 years and 6 months to 12 years and 4 months. The phenotypes of the study patients consisted of 1 hypogonadotrophic hypogonadism, 1 precocious puberty, 3 early puberty, 2 growth hormone deficiency (GHD) (partial) and 1 idiopathic short stature. As shown here t(13;14)(q10;q10) Robertsonian translocation shows a wide range of phenotypes. CONCLUSION: It can be said that t(13;14)(q10;q10) Robertsonian translocation shows various phenotypes from GHD to precocious puberty in children. Further large-scale studies are necessary.


Subject(s)
Child , Female , Humans , Male , Endocrine System Diseases , Growth Hormone , Hypogonadism , Karyotype , Phenotype , Puberty , Puberty, Precocious , Translocation, Genetic
15.
The Journal of Korean Academy of Prosthodontics ; : 11-19, 2013.
Article in Korean | WPRIM | ID: wpr-87092

ABSTRACT

PURPOSE: The aim of this study was to evaluate the heat generation in bone in vitro during the guided flapless drilling procedure and the effect of drilling methods on the heat generation. MATERIALS AND METHODS: A model that has missing the first and second mandibular molars bilaterally was used. In group A, classical flap implant surgery was performed. In group B, flapless implant surgery using surgical guide was performed. In group C, flapless implant surgery using surgical guide without up-and-down pumping motion was performed. Temperature was measured with k-type thermocouple and a real-time digital thermometer. The thermocouples were placed at 0.5 mm away from the osteotomy area at the depths of 3 mm and 6 mm. The measured values were evaluated with independent t-test. RESULTS: The mean temperature generated was 27.2degrees C (SD +/- 2.1degrees C) and 27.5degrees C (SD +/- 2.3degrees C) for groups A and B, respectively. These differences were not statistically significant. In group C, the mean temperature was 37.0degrees C (SD +/- 3.4degrees C). There were statistically significant differences between groups B and C with respect to the mean temperature. CONCLUSION: These findings suggest that guided flapless drilling with up-and-down pumping motion may not significantly increase the bone temperature.


Subject(s)
Dental Implants , Hot Temperature , Mandrillus , Molar , Osteotomy , Thermometers
16.
Journal of the Korean Society of Emergency Medicine ; : 709-715, 2013.
Article in Korean | WPRIM | ID: wpr-73507

ABSTRACT

PURPOSE: Spontaneous intestinal intramural hematoma (SIMH) is a very rare complication of anticoagulation. Most reports on SIMH have been case reports and case series, not well-established clinical studies. Therefore, the aim of this study was to evaluate the clinical characteristics and outcomes from SIMH. METHODS: A retrospective review of the records of 48 patients with non-traumatic SIMH was performed at an urban academic tertiary hospital between January 2001 and December 2012. These patients were diagnosed with SIMH by computed tomography and confirmed by a radiology specialist. Their clinical characteristics and outcomes from SIMH were determined. RESULTS: Among all SIMH cases, the percentage of warfarin users was 70.8%. The median age at presentation was 66.5 years, whereas warfarin users were older (68.0 years) than non-users (55.0 years) (p<0.01). SIMH patients had abdominal pain (81.3%), nausea and vomiting (50.0%) and 62.5% of them had abdominal tenderness. The most frequently involved site was the small bowel (85.4%) and there was only one patient with bowel obstruction from SIMH. A total of 33(68.6%) patients were admitted for 9.3 days for conservative treatment, including transfusion. On the other hand, two patients had surgical intervention. There were no mortality cases from SIMH during the study period. CONCLUSION: SIMH is rare disease which can treated with supportive care. However, it can cause severe complications, such as bowel obstruction and perforation, requiring surgical intervention. Therefore, emergency physicians have to consider SIMH carefully, especially in patients treated with an anticoagulation agent.


Subject(s)
Humans , Abdominal Pain , Emergencies , Hand , Hematoma , Intestines , Mortality , Nausea , Rare Diseases , Retrospective Studies , Specialization , Tertiary Care Centers , Vomiting , Warfarin
17.
Annals of Pediatric Endocrinology & Metabolism ; : 179-182, 2013.
Article in English | WPRIM | ID: wpr-10174

ABSTRACT

PURPOSE: It has been reported that antithroglobulin (anti-TG) antibody is increased in the sera of both children with transient congenital hypothyroidism and their mothers. And transplacental transport of thyroid autoantibody was proposed as the pathogenesis of transient congenital hypothyroidism. However this is not known in nontransient congenital hypothyroidism. This study was done to see changes of anti-TG antibody in children with nontransient congenital hypothyroidism. METHODS: Study patients consisted of 60 patients diagnosed as congenital hypothyroidism in the Department of Pediatrics, Kyungpook National University Children's Hospital, Daegu, Republic of Korea between January 2010 and March 2013. Healthy control were 45 children showing normal thyroid function. Anti-TG antibody and various laboratory tests were analyzed retrospectively, and compared in both children with congenital hypothyroidism and controls. RESULTS: Anti-TG antibody was significantly higher in children with congenital hypothyroidism compared to healthy controls, 119.4+/-34.7 U/mL versus 80.6+/-19.6 U/mL, respectively (P<0.001). There was no significant difference of anti-TG antibody in gender and age. CONCLUSION: We observed a significant increase of anti-TG antibody in children with nontransient congenital hypothyroidism compared to healthy controls. Further study focusing pathogenetic role of anti-TG antibody in nontransient congenital hypothyroidism is necessary. Furthermore, the clinical significance in the course of congenital hypothyroidism need to be known.


Subject(s)
Child , Humans , Autoantibodies , Congenital Hypothyroidism , Mothers , Pediatrics , Republic of Korea , Retrospective Studies , Thyroid Gland
18.
Journal of The Korean Society of Clinical Toxicology ; : 80-85, 2012.
Article in Korean | WPRIM | ID: wpr-190993

ABSTRACT

PURPOSE: The aim of this study was to describe the epidemiologic characteristics of adult patients with carbon monoxide poisoning who presented to the emergency department in recent years. METHODS: This was a retrospective cohort study on adult consecutive patients with carbon monoxide (CO) poisoning who presented to the emergency department of a tertiary care university-affiliated hospital from January 1, 2008 to December 31, 2011. RESULTS: A total of 91 patients were included in this study; there were 56(61.5%) unintentional and 35(38.5%) intentional poisonings. For the unintentional CO poisonings, the principal sources of exposure to CO were fire (39.3%), charcoal (17.9%), briquette charcoal (7.1%), wood burning boiler (7.1%), gas boiler (5.4%), automobile heater (3.6%), briquette boiler (3.6%), firewood (3.6%), and other items (12.5%). For the intentional CO poisonings, the sources were ignition charcoal (60.0%), briquette (31.4%), charcoal (5.7%) and butane gas (2.9%). For the unintentional CO poisonings, the places of poisoning were the home (58.9%), workplace (10.7%), public accommodation (8.9%), tent (8.9%), automobile (3.6%) and parking place (1.8%). For the intentional CO poisonings, the places of poisoning were the home (77.1%), public accommodation (11.4%) and automobile (11.4%). The proportion of intentional CO poisonings among total poisonings has increased significantly in recent years; 0.0% in 2008, 3.3% in 2009, 5.5% in 2010, and 29.7% in 2011. CONCLUSION: This study showed that in recent years in Korea, the source of CO has diversified broadly and intentional CO poisonings from burning ignition charcoal or briquettes has increased. Prevention efforts should consider these factors.


Subject(s)
Adult , Humans , Automobiles , Burns , Butanes , Carbon , Carbon Monoxide , Carbon Monoxide Poisoning , Charcoal , Cohort Studies , Emergencies , Fires , Hypogonadism , Korea , Mitochondrial Diseases , Ophthalmoplegia , Retrospective Studies , Tertiary Healthcare , Wood
19.
The Journal of Korean Academy of Prosthodontics ; : 271-278, 2012.
Article in Korean | WPRIM | ID: wpr-33060

ABSTRACT

PURPOSE: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. MATERIALS AND METHODS: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. RESULTS: The gap between the surgical guide and the model was 1.4 +/- 0.3 mm and 0.4 +/- 0.3 mm for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of 3.9 +/- 1.6degrees, buccolingual angular deviation of 2.7 +/- 1.5degrees and vertical deviation of 1.9 +/- 0.9 mm, whereas the positioning device showed mesiodistal angular deviation of 0.7 +/- 0.3degrees, buccolingual angular deviation of 0.3 +/- 0.2degrees and vertical deviation of 0.4 +/- 0.2 mm. The differences were statistically significant between the two groups (P<.05). CONCLUSION: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.


Subject(s)
Dental Clinics , Surgery, Computer-Assisted , Tooth Loss
SELECTION OF CITATIONS
SEARCH DETAIL